se agrego el registro de la conexión en la base de datos
This commit is contained in:
@@ -9,6 +9,7 @@ Imports System.Configuration
|
||||
Imports Microsoft.Reporting.WebForms
|
||||
Imports System.Xml
|
||||
Imports System.IO
|
||||
Imports System.Web
|
||||
|
||||
Public Class ClsBancos
|
||||
Implements IDisposable
|
||||
@@ -47,10 +48,12 @@ Public Class ClsBancos
|
||||
Public Property CveUsuarioCancelacion As Integer
|
||||
Public Property UsuarioCancelacion As String
|
||||
Public Property FechaIngCancelacion As Date
|
||||
Public Property FechaCancelacion As Date
|
||||
|
||||
Public Property FechaCancelacion As Date
|
||||
|
||||
'CONTROL DE LA CONEXION
|
||||
Private CveConexion As Integer = 0
|
||||
#End Region
|
||||
|
||||
|
||||
#Region " P R O P I E D A D E S - B A N C O S - I E"
|
||||
Public Property CveIE As Integer
|
||||
Public Property CveCuenta As Integer
|
||||
@@ -175,19 +178,28 @@ Public Class ClsBancos
|
||||
If TransaccionCompartida Is Nothing Then
|
||||
SqlConexion = New SqlConnection
|
||||
SqlConexion.ConnectionString = ConfigurationManager.ConnectionStrings("Conexion").ConnectionString
|
||||
SqlCommand = New SqlCommand("", SqlConexion)
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
Try
|
||||
SqlConexion.Open()
|
||||
ConexionAdd(HttpContext.Current.Request.Url.AbsolutePath.ToString)
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error al intentar conectarse a la base de datos.", ex)
|
||||
OnError("Ocurrió un error al intentar conectarse a la base de datos.", ex)
|
||||
End Try
|
||||
Else
|
||||
SqlConexion = TransaccionCompartida.Connection
|
||||
SqlTransacc = TransaccionCompartida
|
||||
SqlCommand = New SqlCommand("", SqlConexion)
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
End If
|
||||
|
||||
SqlCommand = New SqlCommand("", SqlConexion)
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
|
||||
'SqlCommand = New SqlCommand("", SqlConexion)
|
||||
'SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
'Try
|
||||
' ConexionAdd(HttpContext.Current.Request.Url.AbsolutePath.ToString)
|
||||
'Catch ex As Exception
|
||||
|
||||
'End Try
|
||||
End Sub
|
||||
Private Sub DataAdapter(StrSQL As String, Optional TipoComando As CommandType = CommandType.StoredProcedure)
|
||||
With SqlAdapter.SelectCommand
|
||||
@@ -197,7 +209,49 @@ Public Class ClsBancos
|
||||
End With
|
||||
If Not SqlTransacc Is Nothing Then SqlAdapter.SelectCommand.Transaction = SqlTransacc
|
||||
Data = New DataTable
|
||||
End Sub
|
||||
|
||||
#Region "Conexiones"
|
||||
|
||||
Private Sub ConexionAdd(Url As String)
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
'DataAdapter(String.Format("INSERT INTO Sis_Conexiones (Clase,Modulo) VALUES ('ClsRH','{0}')", "RH/CatMotivosBaja"), CommandType.Text) ' pendiente de terminar parra registrar el cveconexion, falta el rarámetro de módulo
|
||||
DataAdapter("PA_Sis_RegistrarConexion")
|
||||
With SqlAdapter.SelectCommand.Parameters
|
||||
.Add("@Clase", SqlDbType.VarChar).Value = Me.GetType().Name
|
||||
'.Add("@Modulo", SqlDbType.VarChar).Value = HttpContext.Current.Request.Url.AbsolutePath.ToString
|
||||
.Add("@Modulo", SqlDbType.VarChar).Value = Url
|
||||
.Add("@IDConexion", SqlDbType.Int).Direction = ParameterDirection.Output
|
||||
End With
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
CveConexion = SqlAdapter.SelectCommand.Parameters("@IDConexion").Value.ToString.ToEntero
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
End Sub
|
||||
|
||||
Private Sub ConexionClose()
|
||||
If CveConexion > 0 AndAlso ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("UPDATE Sis_Conexiones SET FechaCierre = GETDATE() WHERE CveConexion = {0}", CveConexion), CommandType.Text)
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
|
||||
End Sub
|
||||
#End Region
|
||||
|
||||
Private Sub DataCommand(pStrSQL As String, Optional TipoComando As CommandType = CommandType.StoredProcedure)
|
||||
With SqlCommand
|
||||
.Parameters.Clear()
|
||||
@@ -4066,8 +4120,9 @@ Public Class ClsBancos
|
||||
'End Sub
|
||||
|
||||
' This code added by Visual Basic to correctly implement the disposable pattern.
|
||||
Public Sub Dispose() Implements IDisposable.Dispose
|
||||
' Do not change this code. Put cleanup code in Dispose(disposing As Boolean) above.
|
||||
Public Sub Dispose() Implements IDisposable.Dispose
|
||||
' Do not change this code. Put cleanup code in Dispose(disposing As Boolean) above.
|
||||
ConexionClose()
|
||||
Dispose(True)
|
||||
GC.SuppressFinalize(Me)
|
||||
End Sub
|
||||
|
||||
@@ -19,10 +19,12 @@ Public Class ClsCompras
|
||||
Private StrSQL As StringBuilder
|
||||
|
||||
'Atributos de la clase
|
||||
Private disposedValue As Boolean = False ' Para detectar llamadas redundantes
|
||||
|
||||
Private disposedValue As Boolean = False ' Para detectar llamadas redundantes
|
||||
'REGISTRAR CONEXIONES ABIERTAS
|
||||
Private CveConexion As Integer = 0
|
||||
|
||||
#End Region
|
||||
|
||||
|
||||
#Region "Propiedades"
|
||||
Public ReadOnly Property DtResultados() As DataTable
|
||||
Get
|
||||
@@ -53,17 +55,20 @@ Public Class ClsCompras
|
||||
If TransaccionCompartida Is Nothing Then
|
||||
SqlConexion = New SqlConnection
|
||||
SqlConexion.ConnectionString = ConfigurationManager.ConnectionStrings("Conexion").ConnectionString
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
Try
|
||||
SqlConexion.Open()
|
||||
ConexionAdd()
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error al intentar conectarse a la base de datos.", ex)
|
||||
End Try
|
||||
Else
|
||||
SqlConexion = TransaccionCompartida.Connection
|
||||
SqlTransacc = TransaccionCompartida
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
End If
|
||||
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
'SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
|
||||
End Sub
|
||||
|
||||
@@ -75,10 +80,48 @@ Public Class ClsCompras
|
||||
End With
|
||||
Data = New DataTable
|
||||
If SqlTransacc IsNot Nothing Then SqlAdapter.SelectCommand.Transaction = SqlTransacc
|
||||
End Sub
|
||||
|
||||
#Region "Conexiones"
|
||||
|
||||
Private Sub ConexionAdd()
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
'DataAdapter(String.Format("INSERT INTO Sis_Conexiones (Clase,Modulo) VALUES ('ClsRH','{0}')", "RH/CatMotivosBaja"), CommandType.Text) ' pendiente de terminar parra registrar el cveconexion, falta el rarámetro de módulo
|
||||
DataAdapter("PA_Sis_RegistrarConexion")
|
||||
With SqlAdapter.SelectCommand.Parameters
|
||||
.Add("@Clase", SqlDbType.VarChar).Value = Me.GetType().Name
|
||||
.Add("@Modulo", SqlDbType.VarChar).Value = HttpContext.Current.Request.Url.AbsolutePath.ToString
|
||||
.Add("@IDConexion", SqlDbType.Int).Direction = ParameterDirection.Output
|
||||
End With
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
CveConexion = SqlAdapter.SelectCommand.Parameters("@IDConexion").Value.ToString.ToEntero
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
End Sub
|
||||
|
||||
Private Sub ConexionClose()
|
||||
If CveConexion > 0 AndAlso ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("UPDATE Sis_Conexiones SET FechaCierre = GETDATE() WHERE CveConexion = {0}", CveConexion), CommandType.Text)
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
|
||||
End Sub
|
||||
#End Region
|
||||
|
||||
Public Function GetCompras(CveCompra As Integer, Serie As String, Folio As String, CveProveedor As Integer, IdPoliza As Integer, CveEmpresa As Integer, Optional ProveedorRFC As String = "-1") As Boolean
|
||||
Dim Retorno As Boolean = False
|
||||
DataAdapter("PA_Comp_ComprasGet")
|
||||
@@ -1838,6 +1881,7 @@ Public Class ClsCompras
|
||||
' This code added by Visual Basic to correctly implement the disposable pattern.
|
||||
Public Sub Dispose() Implements IDisposable.Dispose
|
||||
' Do not change this code. Put cleanup code in Dispose(disposing As Boolean) above.
|
||||
ConexionClose()
|
||||
Dispose(True)
|
||||
GC.SuppressFinalize(Me)
|
||||
End Sub
|
||||
|
||||
@@ -83,7 +83,7 @@ Public Class ClsRH
|
||||
'DataAdapter(String.Format("INSERT INTO Sis_Conexiones (Clase,Modulo) VALUES ('ClsRH','{0}')", "RH/CatMotivosBaja"), CommandType.Text) ' pendiente de terminar parra registrar el cveconexion, falta el rarámetro de módulo
|
||||
DataAdapter("PA_Sis_RegistrarConexion")
|
||||
With SqlAdapter.SelectCommand.Parameters
|
||||
.Add("@Clase", SqlDbType.VarChar).Value = "ClsRH"
|
||||
.Add("@Clase", SqlDbType.VarChar).Value = Me.GetType().Name
|
||||
.Add("@Modulo", SqlDbType.VarChar).Value = HttpContext.Current.Request.Url.AbsolutePath.ToString
|
||||
.Add("@IDConexion", SqlDbType.Int).Direction = ParameterDirection.Output
|
||||
End With
|
||||
@@ -99,7 +99,7 @@ Public Class ClsRH
|
||||
End Sub
|
||||
|
||||
Private Sub ConexionClose()
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
If CveConexion > 0 AndAlso ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("UPDATE Sis_Conexiones SET FechaCierre = GETDATE() WHERE CveConexion = {0}", CveConexion), CommandType.Text)
|
||||
|
||||
|
||||
@@ -81,6 +81,7 @@ Public Class ClsVentas
|
||||
If TransaccionCompartida Is Nothing Then
|
||||
SqlConexion = New SqlConnection
|
||||
SqlConexion.ConnectionString = ConfigurationManager.ConnectionStrings("Conexion").ConnectionString
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
Try
|
||||
SqlConexion.Open()
|
||||
ConexionAdd()
|
||||
@@ -90,9 +91,10 @@ Public Class ClsVentas
|
||||
Else
|
||||
SqlConexion = TransaccionCompartida.Connection
|
||||
SqlTransacc = TransaccionCompartida
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
End If
|
||||
|
||||
SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
'SqlAdapter = New SqlDataAdapter("", SqlConexion)
|
||||
|
||||
End Sub
|
||||
Private Sub DataAdapter(ByVal pStrSQL As String, Optional ByVal TipoComando As CommandType = CommandType.StoredProcedure)
|
||||
@@ -105,41 +107,43 @@ Public Class ClsVentas
|
||||
Data = New DataTable
|
||||
End Sub
|
||||
|
||||
#Region "Conexiones"
|
||||
|
||||
Private Sub ConexionAdd()
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("INSERT INTO Sis_Conexiones (Clase,Modulo) VALUES ('ClsVentas',{0})", HttpContext.Current.Request.Url.Authority), CommandType.Text) ' pendiente de terminar parra registrar el cveconexion, falta el rarámetro de módulo
|
||||
With SqlAdapter.SelectCommand.Parameters
|
||||
|
||||
.Add("@CveConexion", SqlDbType.Int).Direction = ParameterDirection.Output
|
||||
End With
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
CveConexion = SqlAdapter.SelectCommand.Parameters("@Opcion").Value.ToString.ToEntero
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
End Sub
|
||||
|
||||
Private Sub ConexionClose()
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("UPDATE Sis_Conexiones SET FechaCierre = GETDATE WHERE CveConexion = ", CveConexion), CommandType.Text)
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
#Region "Conexiones"
|
||||
|
||||
Private Sub ConexionAdd()
|
||||
If ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
'DataAdapter(String.Format("INSERT INTO Sis_Conexiones (Clase,Modulo) VALUES ('ClsRH','{0}')", "RH/CatMotivosBaja"), CommandType.Text) ' pendiente de terminar parra registrar el cveconexion, falta el rarámetro de módulo
|
||||
DataAdapter("PA_Sis_RegistrarConexion")
|
||||
With SqlAdapter.SelectCommand.Parameters
|
||||
.Add("@Clase", SqlDbType.VarChar).Value = Me.GetType().Name
|
||||
.Add("@Modulo", SqlDbType.VarChar).Value = HttpContext.Current.Request.Url.AbsolutePath.ToString
|
||||
.Add("@IDConexion", SqlDbType.Int).Direction = ParameterDirection.Output
|
||||
End With
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
CveConexion = SqlAdapter.SelectCommand.Parameters("@IDConexion").Value.ToString.ToEntero
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
End Sub
|
||||
|
||||
Private Sub ConexionClose()
|
||||
If CveConexion > 0 AndAlso ConfigurationManager.AppSettings("RegistraConexion") IsNot Nothing AndAlso ConfigurationManager.AppSettings("RegistraConexion").ToString() = "1" Then
|
||||
|
||||
DataAdapter(String.Format("UPDATE Sis_Conexiones SET FechaCierre = GETDATE() WHERE CveConexion = {0}", CveConexion), CommandType.Text)
|
||||
|
||||
Try
|
||||
SqlAdapter.Fill(Data)
|
||||
|
||||
Catch ex As Exception
|
||||
OnError("Ocurrió un error registrar la conexión.", ex, SqlAdapter.SelectCommand.Parameters.ParametrosInfo)
|
||||
End Try
|
||||
|
||||
End If
|
||||
|
||||
End Sub
|
||||
#End Region
|
||||
|
||||
@@ -3963,6 +3967,7 @@ Public Class ClsVentas
|
||||
' This code added by Visual Basic to correctly implement the disposable pattern.
|
||||
Public Sub Dispose() Implements IDisposable.Dispose
|
||||
' Do not change this code. Put cleanup code in Dispose(disposing As Boolean) above.
|
||||
ConexionClose()
|
||||
Dispose(True)
|
||||
GC.SuppressFinalize(Me)
|
||||
End Sub
|
||||
|
||||
Reference in New Issue
Block a user