Guardar Modelo y BCI

This commit is contained in:
janeth arvizu
2019-10-16 11:18:48 -07:00
parent e3174579e9
commit 5691ce3de7
2 changed files with 51 additions and 7 deletions

View File

@@ -2658,24 +2658,41 @@
<br />
<asp:TextBox ID="TxtObsPS" runat="server" Height="100%" Width="100%" TextMode="MultiLine" CausesValidation="true" MaxLength="500"></asp:TextBox>
</div>
<div class="col-md-5" id="DivRecepcionUsados" runat="server" visible="false">
</div>
<br />
<div class="row">
<div class="col-md-12" id="DivRecepcionUsados" runat="server" visible="false">
<asp:GridView ID="GvRecepcionUsados" runat="server" GridLines="None" ShowHeaderWhenEmpty="true" CssClass="table table-hover table-striped ScrollAD mysmallbtn"
data-sort="true" BorderWidth="1" BorderColor="#D3D3D3" CellSpacing="0" Width="100%" AutoGenerateColumns="False" data-height="100"
DataKeyNames="CvePSCargo,CveUM,Cargo,CveTamaño">
<Columns>
<asp:BoundField DataField="CodigoPS" HeaderText="Tamaño" ItemStyle-HorizontalAlign="Left" ItemStyle-Width="70%" />
<asp:TemplateField HeaderText="Cantidad" ItemStyle-HorizontalAlign="Center" ItemStyle-Width="30%">
<asp:BoundField DataField="CodigoPS" HeaderText="Tamaño" ItemStyle-HorizontalAlign="Left" ItemStyle-Width="35%" />
<asp:TemplateField HeaderText="Cantidad" ItemStyle-HorizontalAlign="Center" ItemStyle-Width="20%">
<ItemTemplate>
<asp:TextBox ID="TxtCantidad" runat="server" Width="80%"></asp:TextBox>
<asp:TextBox ID="TxtCantidad" CssClass="form-control linewhitsize" runat="server" Width="90%" Height="30px"></asp:TextBox>
<ajax:FilteredTextBoxExtender ID="FTBECantidad" runat="server" TargetControlID="TxtCantidad" FilterType="Custom, Numbers" ValidChars="." />
</ItemTemplate>
</asp:TemplateField>
<asp:TemplateField HeaderText="Modelo" ItemStyle-HorizontalAlign="Center" ItemStyle-Width="30%">
<ItemTemplate>
<asp:DropDownList ID="DdlModeloAuto" CssClass="form-control input-sm select2me" runat="server" AppendDataBoundItems="true" CausesValidation="true" DataTextField="ModeloMarca" DataValueField="CveModeloAuto" >
</asp:DropDownList>
</ItemTemplate>
</asp:TemplateField>
<asp:TemplateField HeaderText="BCI" ItemStyle-HorizontalAlign="Center" ItemStyle-Width="25%">
<ItemTemplate>
<asp:DropDownList ID="DdlBCIUsado" CssClass="form-control input-sm select2me" runat="server" AppendDataBoundItems="true" CausesValidation="true" DataTextField="BCI" DataValueField="CveBCIUsado" Width="90%">
</asp:DropDownList>
</ItemTemplate>
</asp:TemplateField>
</Columns>
</asp:GridView>
</div>
</div>
<%-- <br />
<%-- <br />
<div class="row">
<div class="col-md-7">
<label>BCI:</label>

View File

@@ -2770,6 +2770,13 @@ Partial Class PV
'Muestra la tabla de tamaños
If drPS("CveTamaño").ToString().ToEntero() > 0 Then
DivRecepcionUsados.Visible = True
If DdlTipoComprobante.SelectedValue <> "Rem" Then
GvRecepcionUsados.Columns(2).Visible = False
GvRecepcionUsados.Columns(3).Visible = False
Else
GvRecepcionUsados.Columns(2).Visible = True
GvRecepcionUsados.Columns(3).Visible = True
End If
End If
DdlUnidadMedida.Items.Clear()
@@ -4904,6 +4911,7 @@ Partial Class PV
GvRecepcionUsados.DataSource = DtTamanios
GvRecepcionUsadosModal.DataSource = DtTamanios
DdlFolioGarantia.DataBind()
DdlTipoUso.DataBind()
DdlTipoDefecto.DataBind()
@@ -4919,6 +4927,25 @@ Partial Class PV
DivChkAjuste.Visible = True
End Sub
Protected Sub GvRecepcionUsados_RowDataBound(ByVal sender As Object, ByVal e As System.Web.UI.WebControls.GridViewRowEventArgs) Handles GvRecepcionUsados.RowDataBound
If e.Row.RowType = DataControlRowType.DataRow Then
Dim ObjGral As New ClsGenerales
If ObjGral.BCIUsadoGet(UsuarioActual.CveEmpresa) Then
e.Row.FCDropDownList("DdlBCIUsado").DataSource = ObjGral.DtResultados
End If
'DdlBCIUsado.Items.Insert(0, New ListItem("Seleccione", "-1"))
'DdlBCIUsado.SelectedValueExist(-1)
e.Row.FCDropDownList("DdlBCIUsado").DataBind()
'e.Row.FCDropDownList("DdlBCIUsado").SelectedValue = e.Row.DBCampo("CveBCIUsado")
If ObjGral.ModelosAutosGet(UsuarioActual.CveEmpresa) Then
e.Row.FCDropDownList("DdlModeloAuto").DataSource = ObjGral.DtResultados
End If
e.Row.FCDropDownList("DdlModeloAuto").DataBind()
End If
End Sub
Private Sub CargaPSAjuste()
DdlPSAjuste.Items.Clear()
DtPUFacturas.Rows.Clear()
@@ -5321,8 +5348,8 @@ Partial Class PV
Row("CveUM") = Gvr.DataKey("CveUM").ToEntero
Row("CveVentaDetalle") = -1
Row("PU") = Gvr.DataKey("Cargo").ToDouble
Row("CveBCIUsado") = -1
Row("CveModeloAuto") = -1
Row("CveBCIUsado") = Gvr.FCDropDownList("DdlBCIUsado").SelectedValue.ToEntero
Row("CveModeloAuto") = Gvr.FCDropDownList("DdlModeloAuto").SelectedValue.ToEntero
TmpDTRecepcionUsados.Rows.Add(Row)
End If